Nearly every major manufacturer is conducting fire tests, thermal-runaway demonstrations, and container-level fire and explosion experiments. Although there is no single unified standard governing every test, companies are competing in different ways: some compare separation distances, some compare test duration, some emphasize cell capacity, and others even conduct tests with cabinet doors left open.
Fire testing is unquestionably an important means of verifying the safety limits of energy storage systems. But behind all the noise lies a difficult question: more and more tests are becoming tests performed simply for the sake of burning equipment.
When dramatic fires become marketing material and publicity talking points, the industry must ask:
What are all these fire tests actually supposed to demonstrate?
In October 2026, Sungrow's PowerTitan 3.0 completed a milestone extreme-fire validation test. From PowerTitan 1.0 and 2.0 to 3.0, all three generations of its utility-scale energy storage products reportedly passed their respective tests on the first attempt, with each test validating different technologies under extreme safety conditions.
This experience led to an important industry insight:
True energy storage safety is not "burned into" a product. It is systematically designed into it.
1. Why Is Everyone Competing in Fire Testing?
Before discussing what fire testing should demonstrate, it is necessary to understand why energy storage companies are rushing to conduct these tests.
This trend reflects the industry's growing emphasis on safety, but it is also being driven by increasingly stringent market-access requirements.
Large-scale fire testing is primarily associated with the standards summarized below. Although companies do not all follow the same requirements, continued market practice and technical development have gradually produced a degree of industry consensus.
|
Standard |
Issuing Organization |
Main Content and Scope |
|
UL 9540A, Sixth Edition |
UL Solutions, United States |
A test method for evaluating thermal-runaway fire propagation in battery energy storage systems. The sixth edition, issued in March 2026, extends safety validation from the cell and module levels to full cabinets and realistic installation-level fire scenarios. It has reportedly been adopted by regulators in the United States, Europe, Australia, the Middle East, and other markets as an additional market-access requirement. |
|
UL 9540B |
UL Solutions, United States |
A safety standard for residential energy storage systems rated at 20 kWh or less. It requires thermal runaway to be initiated at full state of charge and evaluates extreme scenarios such as combustible-gas accumulation and external ignition, without fire-suppression intervention during the test. |
|
NFPA 855, 2026 Edition |
National Fire Protection Association |
A North American fire-safety standard widely referenced by authorities having jurisdiction when accepting and inspecting energy storage systems. Annex G.11 of the 2026 edition elevates large-scale fire testing to a core testing guideline and requires evaluation of the risk of coordinated fire propagation across multiple battery clusters. |
|
CSA TS-800 |
Canadian Standards Association |
A technical specification addressing large-scale fire testing of energy storage containers under extreme operating conditions. |
|
CSA/ANSI C-800:25 |
CSA Group, March 2025 |
An extension of TS-800 that goes beyond conventional safety and performance testing. It evaluates the durability of energy storage systems under extreme environmental conditions, mechanical impacts, other forms of abuse, and large-scale fire-test scenarios. |
|
GB 44240-2024 |
Standardization Administration of China |
Safety Requirements for Lithium Cells and Batteries Used in Electrical Energy Storage Systems. China's first mandatory national safety standard for energy storage batteries, implemented in August 2025, marking an important step in the country's safety regulation of lithium batteries used in energy storage. |
Together, UL 9540A, Sixth Edition; NFPA 855, 2026 Edition; and CSA C-800 have effectively created several internationally recognized "admission tickets" for fire testing.
These standards are a major external force driving companies into the large-scale fire-testing race.
2. What Exactly Is Being Burned?
Although nearly every energy storage company appears to be joining this highly visible container-burning competition, many participants have not clearly explained what their tests are actually intended to prove.
The test level matters enormously. Different test levels validate completely different safety characteristics, and their technical value varies substantially.
Fire tests conducted within the industry over the past two years can generally be divided into four levels.
Cell Level
A single cell is tested to evaluate its inherent thermal stability and heat release rate.
This is a fundamental test for cell manufacturers. It represents the behavior of the individual cell only and provides limited information about the safety of a complete energy storage system.
Module Level
Multiple cells are assembled into a module to determine whether thermal runaway initiated in one cell will propagate to other cells within the module.
Many externally promoted "fire tests" remain at this level. These tests are relatively small, inexpensive, and easy to control.
Battery Cabinet or Cluster Level
An entire energy storage battery cabinet is tested, including its:
Battery management system
Wiring harnesses
Structural components
Pressure-relief pathways
The primary question is whether thermal runaway in one cell will propagate to other cells in the same cabinet.
Testing at this level begins to address system-level behavior, but it still does not fully represent a real energy storage facility.
Installation or Site Level
Multiple containers or cabinets are tested together with a complete configuration that may include:
Medium-voltage equipment
Power-conversion systems
Liquid-cooling systems
Specified separation distances
Electrical interconnections
This level addresses the most serious question: If one container catches fire, will it ignite an adjacent container and trigger a cascading fire or explosion across the entire facility?
In simpler terms, it does not merely ask whether an individual cell behaves safely. It asks whether thermal runaway will propagate through the battery enclosure and whether installation-level safety can be demonstrated.
This is the level generally associated with a Large-Scale Fire Test (LSFT).
However, many of the industry's current problems also arise at this level. A common joke has emerged:
"If you haven't burned a few cabinets, you can hardly claim to be in the energy storage business."
This attitude encourages companies to conduct fire tests for publicity rather than technical validation. Some smaller companies have even presented videos of modules or small cabinets burning as evidence of "installation-level safety," potentially misleading the public.
More importantly, many tests retain active sprinkler systems and thermal-management protection throughout the experiment. Such tests demonstrate "safety when rescue systems are functioning." Their main purpose is to determine whether a fire can be controlled when the protective systems operate normally.
True extreme-condition safety, however, is determined by what remains when every active protection system has failed.
Meaningful extreme-condition testing therefore requires the technical confidence to perform validation with active fire suppression disabled and thermal-management systems shut down.
The test is no longer evaluating emergency intervention. It is evaluating the underlying safety of the system's inherent architecture.
3. What Should Fire Testing Actually Demonstrate?
First: Quantify Extreme Risks
Fire testing should generate fallback safety data for rare, high-consequence "black swan" scenarios.
Second: Support Quantitative Risk Management
The results should address the risk-control requirements of investors and insurers, helping protect the safety and long-term returns of energy storage assets.
Third: Drive Architectural Improvement
Testing should expose weaknesses and force improvements in inherently safe design throughout the entire system, from cells and modules to cabinets and complete installations.
Fourth: Support the Evolution of Industry Standards
Test data should help improve industry standards and establish credible validation frameworks for specific energy storage applications.