Flame Propagation Calorimeter

Export Model: FTech-ISO12136
Standard Used: ISO12136
Send Inquiry
Description
Technical Parameters

TESTech Instrument (Suzhou) Technologies is one of the leading manufacturers and suppliers of flame propagation calorimeter in China. Welcome to wholesale premium test equipment at competitive price from our factory. If you have any enquiry about quotation, please feel free to email us.

 

Product Overview

 

The Flame Propagation Calorimeter (FPA) characterizes fire behavior in corresponding scale fire tests by measuring the combustibility characteristics of materials.

 

The main measured parameters include time to ignition, mass loss rate, heat release rate including chemical and convective heat release rate, and smoke generation rate.

 

The testing scope covers various materials, components, end products, and polymer materials, but it is not suitable for explosive objects.

 

The test results can be used to evaluate the inherent combustibility of materials and provide a basis for flame spread models, fire development models, hazard assessment, building and product design, and material development.

 

Structural Features

 

  • Standard control cabinet with computer and Labview intelligent control system for convenient operation.
  • Computer controls the entire test process with automatic ignition and automatic combustion time measurement.
  • Infrared heater composed of six 500 W quartz lamps.
  • Four-hole ceramic tube igniter.
  • Stainless steel cold water tank with water flow rate of 2.0 L/min and inlet water temperature not exceeding 20 C.
  • Weighing system uses strain-gauge pressure sensing elements with accuracy up to 0.1 g and weighing range of 0 to 3 kg.

 

Ignition System

 

  • 10 kV spark igniter with safety flameout device.
  • Igniter is automatically positioned by a lever connected to the closing mechanism.
  • Automatic ignition, automatic timing, and automatic gas shutoff on flameout.

 

Exhaust System

 

  • Composed of axial fan, stainless steel exhaust duct, diffuser plate, smoke hood, exhaust pipe, orifice flowmeter, and thermometer.
  • Stainless steel construction extends service life.
  • Includes hood, gas sample probe, exhaust fan with adjustable flow from 0 g/s to 50 g/s and accuracy at least 0.1 g/s, and orifice flow measuring device with thermocouple and differential pressure sensor.
  • Typical testing exhaust flow is 24 L/s.

 

Gas Sampling System

 

  • Includes annular sampler, suction pump, particulate filter, cold trap, exhaust valve, moisture filter, and CO2 filter.
  • Three-stage filtration with filtration accuracy of 0.5 um.
  • Refrigerated cold trap with compressor cooling system and temperature control of 0 to 5 C.
  • Suction pump flow rate 33 L/min, vacuum degree 700 mmHg, pressure 2.5 bar.
  • Drying tube for filtering moisture and impurities.
  • Flow controller for sampling flow control.
  • Sampler has 12 holes opposite to airflow direction, with internal soot filter, located 685 mm from the smoke hood.

 

Measurement System

 

  • Paramagnetic oxygen analyzer with range 0 to 25 percent, imported Servomex oxygen sensor, and linear response.
  • Laser system for smoke density measurement using photodiode, 0.5 mW helium-neon laser, and primary and backup photodetectors; positioning bracket and 0.3 and 0.8 neutral density filters are optional for calibration.
  • High-precision load sensor measures specimen mass change during testing, range 0 to 2000 g, resolution 0.01 g; actual specimen weight requirement is less than 500 g.
  • PID temperature control system with three 1 mm thermocouples for radiant cone temperature measurement and one 1 mm sheathed thermocouple 100 mm above the orifice plate.
  • Exhaust flow is calculated from the pressure difference across a sharp-edged orifice plate with inner diameter 57 mm plus or minus 1 mm, linked to the control system for automatic air velocity control.

 

Calibration System

 

  • Imported Medtherm thermopile heat flux meter with water cooling system, design range 0 to 100 kW/m2, accuracy plus or minus 3 percent, repeatability plus or minus 0.5 percent.
  • Burner calibration system uses methane with purity of 99.5 percent, controlled by methane mass flowmeter.
  • Water cooling system is provided for cooling the imported heat flux meter during operation.

 

User Operation System

 

  • Dedicated Labview control system with friendly interface and precise control.
  • System can display instrument status, calibrate the instrument, store calibration results, collect test data, calculate required parameters, display results according to standards, and average multiple tests.
  • Upper computer communicates with PLC through RS485 communication module for data transmission and motion control.
  • PID temperature control module is linked with the power adjustment module for constant-temperature regulation through the PLC.
  • Signal acquisition and processing module is linked with the airflow circuit control module for intelligent regulation of preset air velocity.
  • Mechanical rotation module is linked with the PLC I/O ports to control the closing state of the rotation mechanism.
  • Glass window and control software facilitate test start, process control, parameter setting, data acquisition, storage, and printing of tables and curves.
  • System stores sample numbers, temperature curves, and test data in the internal database, and supports query by sample number and test date.
  • Gas analyzer can accurately measure O2, CO, and CO2 concentration in gas with accuracy of 0.02 percent.

 

Technical Parameters

 

Parameter

Value

Heat Flux Meter

Thermopile type, design range 0 to 100 kW/m2, accuracy +/- 3%, repeatability +/- 0.5%

Sample Weighing Range

0 to 2000 g, accuracy 0.1 g

Oxygen Analyzer

Paramagnetic type, range 0 to 25%, linear response, 10% to 90% response time less than 12 s, output noise not exceeding 50 ppm, repeatability lower than 100 ppm

CO2 Analyzer

Infrared type, range 0 to 10%, accuracy +/- 0.01%

Exhaust Fan

Adjustable flow 0 to 50 g/s, accuracy 0.1 g/s

Cold Trap

Compressor type, 0 to 5 C

Diaphragm Pump

Flow rate 33 L/min

Detector Performance

Chromaticity standard accuracy +/- 5%, output linearity transmittance less than 1%, absolute transmittance less than 1%

 

Test Data

 

  • Critical heat flux.
  • Thermal response parameter (TRP).
  • Effective heat of combustion.
  • Chemical and convective heat release rate.
  • Flame propagation index (FPI).
  • Smoke generation rate.

 

Key Components

 

Component

Configuration

Thermocouple

Imported Omega, USA, quantity 2

Heat Flux Meter

Imported Medthem, USA, quantity 1

Pressure Gauge

Airtec, Taiwan, quantity 3

Pressure Regulating Valve

Airtec, Taiwan, quantity 3

Solenoid Valve

Shanghai Juliang, quantity 2

PLC Control System

Siemens, quantity 1

Touch Screen

Tiankun Technology, quantity 1

Control Software

Labview, quantity 1

Centrifugal Fan

Taiwan, quantity 1

Micro Differential Pressure Transmitter

Imported, quantity 1

Filter

2 um, quantity 3

Condenser

Compressor operating system, quantity 1

Oxygen Analyzer

Imported sensor, quantity 1

CO2 and CO Analyzer

Infrared analyzer, quantity 1

Smoke Density Light Source

Imported helium-neon laser generator, quantity 1

Silicon Photodiode

Imported from Japan, quantity 1

Exchange Contactor

Schneider, imported brand, quantity 1

Overload Protector

Schneider, imported brand, quantity 1

Circuit Breaker

Schneider, imported brand, several

Cabinet

Standard painted cabinet, quantity 1

Internal Tooling

SUS304 stainless steel, several

 

Customer Preparation Requirements

 

Requirement

Specification

Equipment Size

Overall size 1800 mm x 600 mm x 2400 mm; total height 3200 mm including upward exhaust duct 800 mm

Surrounding Space

Leave at least 1 to 1.5 meters around the equipment

Floor Condition

Flat floor

Air Disturbance

No external airflow is allowed in the room during testing

Exhaust Duct

Provide exhaust duct with outlet diameter 110 mm

Electrical Requirement

220 V, 7000 W, 35 A; incoming power cable at least 6 mm2

Water Supply

Tap water; flow 6 to 12 mL/s; pressure 275 to 620 kPa; temperature 16 to 54 C; no condensation or boiling

Auxiliary Gas

Nitrogen at least 99.5% purity, methane 99.5%, 8.5% CO2, and 0.85% CO; interface pressure within 1 MPa; dry air

Consumables

Asbestos soda lime, calcium sulfate, and silica gel; 500 to 1000 g each

Reference

Constant temperature and humidity room for sample preparation; fire extinguisher in the laboratory

 